Technical specification     Standard Result
composition    
Fibreglass 42% - PVC 58%
openness factor    
NBN EN 410
5.00%
weight    
NF EN 12127
535.00g/m²
thickness    
ISO 5084
0.55mm
density   warp
ISO 7211/2
18.00yarn/cm
weft
14.00yarn/cm
colour fastness to artificial light    
ISO 105 B02
>7
colour fastness to artificial weathering    
ISO 105 B04
>7
tear strength original warp
ISO 4674-1 methode 2
8.50daN
weft
7.50daN
elongation up to break original warp
ISO 1421
3.10%
weft
2.75%
breaking strength original warp
ISO 1421
260.00daN/5 cm
weft
225.00daN/5 cm
elongation up to break after colour fastness to artifical light warp
ISO 1421
4.00%
weft
2.90%
breaking strength after colour fastness to artifical light warp
ISO 1421
240.00daN/5 cm
weft
220.00daN/5 cm
elongation up to break after colour fastness to artifical weathering warp
ISO 1421
3.50%
weft
2.80%
breaking strength after colour fastness to artifical weathering warp
ISO 1421
240.00daN/5 cm
weft
225.00daN/5 cm
tear strength after climatic chamber -30°C warp
ISO 4674-1 methode 2
7.80daN
weft
7.50daN
elongation up to break after climatic chamber -30°C warp
ISO 1421
3.00%
weft
2.50%
breaking strength after climatic chamber -30°C warp
ISO 1421
225.00daN/5 cm
weft
200.00daN/5 cm
tear strength after climatic chamber +70°C warp
ISO 4674-1 methode 2
8.20daN
weft
7.20daN
elongation up to break after climatic chamber +70°C warp
ISO 1421
2.85%
weft
2.50%
breaking strength after climatic chamber +70°C warp
ISO 1421
180.00daN/5 cm
weft
185.00daN/5 cm
air permeability    
ISO 9237
580.00l/m²/s
fire classification Europe   UNE-EN 13501-1:2007 C-s3,d0
fire classification France  
NF P92-503
M1
fire classification Italy  
UNI 9177
Class 1
fire classification Germany  
DIN 4102
B1
fire classification UK  
BS 5867
C
fire classification USA  
NFPA 701
FR
roll length      
50 m / 30 m voor alle breedtes > 270 cm
cleaning      
met water & zeep
confection      
door middel van warmte, hoge frequentie of ultrasoon lassen
Front Back
Interior Exterior Interior Exterior
Front - Exterior
Visual Properties
Tv: Visual light transmittance
8.50%
Tuv: UV transmittance
6.60%
Solar Energetic Properties
As = Solar absorptance
45.20%
Rs = Solar reflectance
43.40%
Ts = Solar transmittance
11.40%
Fabric + Glazing: G-factor
Glazing A Glazing B Glazing C Glazing D
G = Total solar energy transmittance
0.20
0.17
0.12
0.09
Te = Direct solar transmittance
0.10
0.08
0.06
0.03
Qi = Secondary heat transfer factor
0.10
0.08
0.06
0.05
SC = Shading Coefficient
0.24
0.22
0.20
0.27
Classes
Visual comfort
Normal solar transmittance
3
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glare control
1
Privacy night
1
Visual contact with the outside
3
Daylight utilisation
1
Thermal comfort
G-factor = Total solar energy transmittance
Glazing A
2
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
2
Glazing C
3
Glazing D
4
Qi-factor = Secondary heat transfer factor
Glazing A
2
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
3
Glazing C
3
Glazing D
3
Front - Interior
Visual Properties
Tv: Visual light transmittance
8.50%
Tuv: UV transmittance
6.60%
Solar Energetic Properties
As = Solar absorptance
45.20%
Rs = Solar reflectance
43.40%
Ts = Solar transmittance
11.40%
Fabric + Glazing: G-factor
Glazing A Glazing B Glazing C Glazing D
G = Total solar energy transmittance
0.47
0.48
0.43
0.27
Te = Direct solar transmittance
0.10
0.08
0.06
0.04
Qi = Secondary heat transfer factor
0.38
0.40
0.37
0.23
SC = Shading Coefficient
0.56
0.63
0.73
0.85
Classes
Visual comfort
Normal solar transmittance
3
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glare control
1
Privacy night
1
Visual contact with the outside
3
Daylight utilisation
1
Thermal comfort
G-factor = Total solar energy transmittance
Glazing A
1
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
1
Glazing C
1
Glazing D
2
Qi-factor = Secondary heat transfer factor
Glazing A
0
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
0
Glazing C
0
Glazing D
1
Back - Exterior
Visual Properties
Tv: Visual light transmittance
8.50%
Tuv: UV transmittance
6.60%
Solar Energetic Properties
As = Solar absorptance
47.80%
Rs = Solar reflectance
40.80%
Ts = Solar transmittance
11.40%
Fabric + Glazing: G-factor
Glazing A Glazing B Glazing C Glazing D
G = Total solar energy transmittance
0.21
0.17
0.12
0.09
Te = Direct solar transmittance
0.10
0.08
0.06
0.04
Qi = Secondary heat transfer factor
0.11
0.09
0.05
0.05
SC = Shading Coefficient
0.24
0.22
0.20
0.28
Classes
Visual comfort
Normal solar transmittance
3
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glare control
1
Privacy night
1
Visual contact with the outside
3
Daylight utilisation
1
Thermal comfort
G-factor = Total solar energy transmittance
Glazing A
2
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
2
Glazing C
3
Glazing D
4
Qi-factor = Secondary heat transfer factor
Glazing A
2
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
3
Glazing C
3
Glazing D
3
Back - Interior
Visual Properties
Tv: Visual light transmittance
8.50%
Tuv: UV transmittance
6.60%
Solar Energetic Properties
As = Solar absorptance
47.80%
Rs = Solar reflectance
40.80%
Ts = Solar transmittance
11.40%
Fabric + Glazing: G-factor
Glazing A Glazing B Glazing C Glazing D
G = Total solar energy transmittance
0.49
0.49
0.44
0.27
Te = Direct solar transmittance
0.10
0.08
0.06
0.04
Qi = Secondary heat transfer factor
0.39
0.41
0.37
0.24
SC = Shading Coefficient
0.58
0.65
0.74
0.85
Classes
Visual comfort
Normal solar transmittance
3
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glare control
1
Privacy night
1
Visual contact with the outside
3
Daylight utilisation
1
Thermal comfort
G-factor = Total solar energy transmittance
Glazing A
1
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
1
Glazing C
1
Glazing D
2
Qi-factor = Secondary heat transfer factor
Glazing A
0
Class 0: very little effect
Class 1: little effect
Class 2: moderate effect
Class 3: good effect
Class 4: very good effect
Glazing B
0
Glazing C
0
Glazing D
1